Phoenix Contact 2907834, TTC-6P-3-HF-EX-24DC-I-P, Surge protection plug
Surge protection plug with integrated status indicator for a 3-wire Ex i signal circuit with common reference potential. For HF applications. Nominal voltage: 24 V DC
Availability:
3
Quantity:
EA
Phoenix Contact 2908855, MACX MCR-EX-SL-RPSSI-2I-1S, Repeater power supply
Ex i measuring transducer supply conditioner and input signal conditioner, only output 1 is HART-transparent. Transmits supplied or active signals from the Ex area with electrical isolation to two loads. SIL 2 in accordance with IEC 61508, screw connection.
Availability:
10
Quantity:
EA
Phoenix Contact 2908856, MACX MCR-EX-SL-RPSSI-2I-1S-SP, Repeater power supply
Ex i measuring transducer supply conditioner and input signal conditioner, only output 1 is HART-transparent. Transmits supplied or active signals from the Ex area with electrical isolation to two loads. SIL 2 in accordance with IEC 61508, Push-in connection.
Availability:
5
Quantity:
EA
Phoenix Contact 2924029, MACX MCR-EX-SL-RPSSI-I-UP-SP, Power/input isolating amplifier
Ex i repeater power supply and input isolating amplifier, HART Sends fed or active 0/4-20 mA signals from the Ex area to a load (active or passive) to the safe area. Electrical 3-way isolation; SIL 2, wide range power supply.
Availability:
Estimated Lead Time -- 8 days
Quantity:
EA
Phoenix Contact 2924032, MACX MCR-EX-SL-IDSI-I-SP, Output signal conditioner
Ex i output signal conditioner, HART. Isolates and sends intrinsically safe 0/4-20 mA signals to a load (I/P converters, control valves, displays) in Ex areas. Electrical 3-way isolation, wire break recognition, SIL 2 in accordance with IEC 61508, spring-cage connection.
Availability:
Estimated Lead Time -- 8 days
Quantity:
EA
Phoenix Contact 2924142, MACX MCR-EX-SL-RTD-I-SP, Temperature measuring transducer
Ex i temperature measuring transducer: Converts signals from resistance thermometers installed in Ex areas and transmits a 0/4-20 mA signal to a load in the safe area. Freely programmable, 3-way isolation, spring-cage terminal blocks, custom-configured.
Availability:
Estimated Lead Time -- 10 days
Quantity:
EA
Phoenix Contact 2924236, MACX MCR-EX-SL-RPSSI-2I-SP, Repeater power supply
Ex i measuring transducer power supply and input isolating amplifier, HART. Transfers supplied or active 0/4 - 20 mA electrically isolated signals from the Ex area to two loads in the safe area. 4-way electrical isolation, SIL 2 according to IEC 61508, push-in Technology.
Availability:
Estimated Lead Time -- 8 days
Quantity:
EA
Phoenix Contact 2924676, MACX MCR-EX-SL-RPSS-2I-2I-SP, Signal isolator
Ex i measuring transducer repeater power supply, 2-channel; HART-transparent. Supplies Ex i 2-wire measuring transducers and transmits the 4 - 20 mA signal from the Ex area to the safe area. 5-way electrical isolation, up to SIL 3 according to IEC 61508; spring-cage connection.
Availability:
Estimated Lead Time -- 8 days
Quantity:
EA
Phoenix Contact 2924870, MACX MCR-EX-SL-SD-23-48-LFD-SP, Signal isolator
Ex i solenoid driver for controlling Ex i solenoid valves in hazardous areas, logic input, off-load voltage 22.6 V, current limitation at 48 mA, , line fault transparency, error message output, up to SIL 3 according to IEC 61508, Push-in connection
Availability:
3
Quantity:
EA
Phoenix Contact 2924883, MACX MCR-EX-SL-NAM-NAM-SP, Signal isolator
Ex i NAMUR signal conditioners. For operating Ex i proximity sensors and switches in hazardous areas. Passive transistor output (resistive according to EN 60947-5-6), line fault transparency, up to SIL 2 according to IEC 61508; Push-in connection
Availability:
Estimated Lead Time -- 24 days
Quantity:
EA