800-999-7378

Sign In

|

Order Lookup

|

Request Account

|

Phoenix Contact 2900312, PLC-RPT- 24DC/ 1/ACT, Relay Module

Phoenix Contact
Phoenix Contact 2900312, PLC-RPT- 24DC/ 1/ACT, Relay Module

$23.47

/EA

Availability:

Lead Time: 27 bus. days

Qty:
FeaturesTech SpecsAccessoryRelated To...

PLC-INTERFACE for output functions, consisting of PLC-BPT.../ACT basic terminal block with push-in connection and plug-in miniature relay with power contact, for mounting on DIN rail NS 35/7,5, 1 N/O contact, input voltage 24 V DC

$23.47

/EA

Availability:

Lead Time: 27 bus. days

Item ID

PHOENIX 2900312

Manufacturer Part #

2900312

AHC Part #

2340101

Unit Size

1

Brand

Phoenix Contact

Features

  • Actuator connected directly to relay module
  • Efficient connection to system cabling using V8 adapter
  • No need for additional modular terminal blocks
  • Time savings of up to 60 %
  • Relay modules with safe isolation according to DIN EN 50178 between coil and contact
  • Space savings of up to 80 %
  • Functional plug-in bridges

Tech Specifications

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area
Width6.2 mm
Height80 mm
Depth94 mm
Ambient temperature (operation)-40 °C ... 60 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Nominal input voltage U<sub>N</sub>24 V DC
Typical input current at U<sub>N</sub>9 mA
Typical response time5 ms
Typical release time8 ms
Protective circuitReverse polarity protection Polarity protection diode
Protective circuitFree-wheeling diode Damping diode
Operating voltage displayYellow LED
Power dissipation for nominal condition0.22 W
Contact type1 N/O contact
Type of switch contactSingle contact
Contact materialAgSnO
Maximum switching voltage250 V AC/DC (The separating plate PLC-ATP should be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...)
Minimum switching voltage5 V (at 100 mA)
Min. switching current10 mA (at 12 V)
Maximum inrush current10 A (4 s)
Limiting continuous current6 A
Interrupting rating (ohmic load) max.140 W (at 24 V DC)
Interrupting rating (ohmic load) max.20 W (at 48 V DC)
Interrupting rating (ohmic load) max.18 W (at 60 V DC)
Interrupting rating (ohmic load) max.23 W (at 110 V DC)
Interrupting rating (ohmic load) max.40 W (at 220 V DC)
Interrupting rating (ohmic load) max.1500 VA (for 250 V AC)
Switching capacity2 A (at 24 V, DC13)
Switching capacity0.2 A (at 110 V, DC13)
Switching capacity0.1 A (at 220 V, DC13)
Switching capacity3 A (at 24 V, AC15)
Switching capacity3 A (at 120 V, AC15)
Switching capacity3 A (at 230 V, AC15)
Connection nameCoil side
Connection MethodPush-in connection
Stripping length8 mm
Conductor cross section solid0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm² ()
Conductor cross section flexible2x 0.5 mm² ... 1 mm² ()
Conductor cross section AWG26 ... 14
Connection nameContact side
Connection MethodPush-in connection
Stripping length8 mm
Conductor cross section solid0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm² ()
Conductor cross section flexible2x 0.5 mm² ... 1 mm² ()
Conductor cross section AWG26 ... 14
Test voltage relay winding/relay contact4 kV AC (50 Hz, 1 min.)
Operating mode100% operating factor
Degree of protectionRT III (Relay)
Degree of protectionIP20 (Relay base)
Mechanical service life2x 107 cycles
Mounting positionany
Assembly instructionsIn rows with zero spacing
Connection in acc. with standardCUL
DesignationStandards/regulations
Standards/regulationsIEC 60664
Standards/regulationsIEC 60664A
Standards/regulationsDIN VDE 0110
Standards/regulationsDIN EN 50178/DIN VDE 0160 (in relevant parts)
Standards/regulationsDIN EN 50178/VDE 0160
Standards/regulationsIEC 60255/DIN VDE 0435 (in relevant parts)
Degree of pollution3
Overvoltage categoryIII
Flammability rating according to UL 94V0
REACh SVHCLead 7439-92-1
China RoHSEnvironmentally Friendly Use Period = 50
China RoHSFor details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Net weight (SAP)31.27 g

Links

Accessory Items

Related To

This item is a(n)...of the following product...
Accessory
Phoenix Contact 2905137, PLC-V8C/PT-24DC/EM, Extension module
Accessory
Phoenix Contact 2903095, PLC-V8C/SC-24DC/EM, Extension module
Accessory
Phoenix Contact 2907445, PLC-V8C/SC-24DC/SAM2, Controller
Accessory
Phoenix Contact 2907443, PLC-V8C/PT-24DC/SAM2, Controller
Accessory
Phoenix Contact 2907447, PLC-V8C/SC-24DC/BM2, Controller
Accessory
Phoenix Contact 2907446, PLC-V8C/PT-24DC/BM2, Controller

Frequently Purchased Together

Phoenix Contact 2966508, PLC-ESK GY, Power terminal block

Availability:

10 - Bristol, PA -- Storeroom

Qty:

$30.23

/EA

Phoenix Contact 3118135, EBS 10- 8, Insertion bridge

Availability:

13 - Bristol, PA -- Storeroom

Qty:

$9.74

/EA

Phoenix Contact 3004126, UK  5-HESILED 24, Fuse modular terminal block

Availability:

31 - Bristol, PA -- Storeroom

Qty:

$23.10

/EA

Phoenix Contact 2966838, FBST 500-PLC GY, Continuous plug-in bridge

Availability:

22 - Bristol, PA -- Storeroom

Qty:

$33.38

/EA

Phoenix Contact 3030747, ATP-STTB 4, Partition plate

Availability:

154 - Bristol, PA -- Storeroom

Qty:

$1.66

/EA