Phoenix Contact 2904691 PLC-OSC-120UC/48DC/100/V8C/SEN, Solid-state relay module

Phoenix Contact

Availability:

Lead Time: 30 bus. days

Qty:
Tech SpecsAccessory

PLC-INTERFACE for input functions with PLC logic, with screw connection and plug-in miniature solid-state relay, for mounting on DIN rail NS 35/7,5, 1 N/O contact, input: 120 V AC/110 V DC, output: 3 - 48 V DC/100 mA

Availability:

Lead Time: 30 bus. days

Item ID

PHOENIX 2904691

Manufacturer Part #

2904691

AHC Part #

2201459

Unit Size

10

Brand

Phoenix Contact

Tech Specifications

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area
Width6.2 mm
Height80 mm
Depth94 mm
Ambient temperature (operation)-25 °C ... 60 °C
Ambient temperature (storage/transport)-25 °C ... 70 °C
Nominal input voltage U<sub>N</sub>120 V AC (110 V DC)
Nominal input voltage U<sub>N</sub>110 V DC
Input voltage range in reference to U<sub>N</sub>0.8 ... 1.1
Input voltage range96 V AC ... 132 V AC
Input voltage range88 V DC ... 121 V DC
Typical input current at U<sub>N</sub>3.5 mA
Typical response time6 ms (at UN)
Typical turn-off time10 ms (at UN)
Operating voltage displayYellow LED
Type of protectionBridge rectifier
Protective circuit/componentBridge rectifier
Transmission frequency10 Hz
Power dissipation for nominal condition0.42 W
Output voltage range3 V DC ... 48 V DC
Limiting continuous current100 mA
Voltage drop at max. limiting continuous current= 1 V
Output circuit2-wire, floating
Type of protectionReverse polarity protection
Type of protectionSurge protection
Protective circuit/componentPolarity protection diode
Connection nameInput side
Connection MethodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section solid0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.14 mm² ... 2.5 mm²
Conductor cross section AWG26 ... 14
Test voltage input/output2.5 kV (50 Hz, 1 min.)
Mounting positionany
Assembly instructionsIn rows with zero spacing
Operating mode100% operating factor
Flammability rating according to UL 94V0
DesignationStandards/regulations
Standards/regulationsIEC 60664
Standards/regulationsEN 50178
Degree of pollution2
Overvoltage categoryIII
DesignationStandards/regulations
Standards/regulationsIEC 60664
Standards/regulationsEN 50178
InsulationBasic insulation
Degree of pollution2
Overvoltage categoryIII
Flammability rating according to UL 94V0
China RoHSEnvironmentally Friendly Use Period = 50
China RoHSFor details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”